Radio Systems CT-2002 Instruções de Operação Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
Radio Systems, Inc. CT2002 Manual
Page 12
Option 6: Time compare 1. Use the numeric keypad to enter the
minutes and seconds of the time compare. Time between
00:00 and 59:59 must be entered. When the minutes and
seconds of the time of day are equal to the time compare
stored, the matching open collector wired remote will
activate.
Option 7: Time compare 2. See “option 6” above.
Option 8: Time compare 3. See “option 6” above.
Option 9: Time compare 4. See “option 6” above.
Option 10: Top of Hour Reset Offset. A wired remote input is
available for top of hour reset. The default operation
is to reset the time-of-day to 00 min’s. & 00 sec’s.
Use the numeric keypad to reset to a different time,
(minutes and seconds). When the displayed time of day is
within a
+
-
5 minute window of the stored top of hour time
and the wired remote input is activated, the displayed
time will be replaced by the stored top of hour time. (This
function active for stand-alone time-of-day operation
only.)
Option 11: Serial time of day minutes and seconds offset. Use the
numeric keypad to enter the minutes and seconds desired to
be added to the serial time of day data. Use option 4 to input
hours to be added.